USB MagnePrint Swipe Reader with Encryption
30
TRACK_ID_ENABLE PROPERTY
Property ID: 3 (KB mode) or 4 (HID mode)
Property Type: Byte
Length: 1 byte
Get Property: Yes
Set Property: Yes
Default Value: 95 (hex)
Description: This property is defined as follows:
id 0 T
3
T
3
T
2
T
2
T
1
T
1
Id 0 – Decodes standard ISO/ABA cards only
1 – Decodes AAMV and 7-bit cards also
T
#
00 – Track Disabled
01 – Track Enabled
10 – Track Enabled/Required (Error if blank)
This property is stored in non-volatile memory, so it will persist when the unit is
power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled to have these changes take effect. This
device must be unplugged for at least 30 seconds to properly power cycle it.
Example Set TRACK_ID_ENABLE property Request (Hex):
Cmd Num Data Len Prp ID Prp Value
01 02 04 95
Example Set TRACK_ID_ENABLE property Response (Hex):
Result Code Data Len Data
00 00
Example Get TRACK_ID_ENABLE property Request (Hex):
Cmd Num Data Len Prp ID
00 01 04
Example Get TRACK_ID_ENABLE property Response (Hex):
Result Code Data Len Prp Value
00 01 95